When it comes to your TFP200 Scarifier and Deck Scaler, staying on top of regular maintenance is important for smooth operation and efficient application. By following our step-by-step guide on regular checks, you can keep disruptions and costly downtime to a minimum.
Follow our step-by-step daily checks guide
There are a few vital checks that should be undertaken every day as part of your cleaning and maintenance routine.
Here’s how to get started on your TFP200 Scarifier and Deck Scaler daily checks:
- Check that all the electrical cables and connections are secure and undamaged – including the plug socket. Always switch off the machine and disconnect the power supply.
- Check the dust exhaust for blockages and ensure that all hoses, skirt and connections are secure and intact.
- Grease the bearing using SKF general purpose bearing grease. Grease the lift thread above and below the bolts too.
- Check that the cutters, cutter shafts and drum are not excessively worn before installing
- Check drum enclosure is clear of any build ups, and the cutter head is secure and free to rotate with no obstructions.
- Check the belt is correctly tensioned and free from damage. Remove the belt guard using a 12mm socket. For the correct tension, the belt should have 13mm free play.
Get into the habit of these daily checks to save yourself time and money in the long run.
Need help?
To see the daily checks for yourself, watch on YouTube.
To speak to an expert about your Trelawny products, you can contact us via telephone, email or using the form on our website. We’re always happy to help.